Reference number
ISO 10993-18:2020
International Standard
ISO 10993-18:2020
Biological evaluation of medical devices — Part 18: Chemical characterization of medical device materials within a risk management process
Edition 2
2020-01
Preview
ISO 10993-18:2020
64750
недоступно на русском языке
Опубликовано (Версия 2, 2020)
В данный стандарт внесены 1 поправка.

ISO 10993-18:2020

ISO 10993-18:2020
64750
Язык
Формат
CHF 194
Пересчитать швейцарские франки (CHF) в ваша валюта

Тезис

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following:

— the identification of its materials of construction (medical device configuration);

— the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition);

— the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues);

— the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables);

— the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables).

This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15.

The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact).

This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

Общая информация

  •  : Опубликовано
     : 2020-01
    : Опубликование международного стандарта [60.60]
  •  : 2
  • ISO/TC 194
    11.100.20 
  • RSS обновления

 Изменения

Поправки принимаются, когда обнаруживается, что в существующий документ по стандартизации необходимо добавить новый материал. В них также могут быть включены редакционные или технические исправления, которые необходимо внести в существующий документ.

Amendment 1

Determination of the uncertainty factor

Версия 2022

ISO 10993-18:2020/Amd 1:2022
82241
Язык
Формат
CHF 18
Пересчитать швейцарские франки (CHF) в ваша валюта

Жизненный цикл

Цели в области устойчивого развития

Данный стандарт разработан для достижения следующих Цель устойчивого развития

Появились вопросы?

Ознакомьтесь с FAQ